Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add filters








Year range
1.
Indian J Ophthalmol ; 2022 Aug; 70(8): 3083-3087
Article | IMSEAR | ID: sea-224547

ABSTRACT

Purpose: To determine exophthalmometry values (EV) in the north Indian population and to find its correlation with the age, gender, height, weight, body mass index (BMI), locality, and base value of the population. Methods: A total of 1000 eligible participants with 504 females and 496 males with age >5 years were included in this observational cross-sectional study. Age, gender, and locality of the subjects were noted. Hertel’s exophthalmometry was performed on all subjects. The exophthalmometry values and base values were recorded. Height and weight were measured for all participants. BMI was calculated using the parameters. Results: The overall mean exophthalmometry value (mm) was 14.94 ± 2.43 mm with a range between 8 and 22 mm. There was no significant difference in EV between the two eyes. Males recorded a significantly higher mean EV of 15.4 ± 2.51 mm as compared to females with a value of 14.49 ± 2.27 mm. Base value of Hertel’s exophthalmometer had a mean value 100.78 ± 5.63 mm and a range of 84–120 mm. Age, height, weight, BMI, and locality of the subjects were found to have a significant effect on the exophthalmometry as well as the base value of the population. A significant correlation was also seen between exophthalmometry values and base values of the population. Conclusion: Our study provided the normal exophthalmometric range for the north Indian population and also demonstrated the relationship of age, gender, height, weight, BMI, locality, and base value with the exophthalmometric values

2.
Rev. cuba. oftalmol ; 33(3): e878, graf
Article in Spanish | LILACS, CUMED | ID: biblio-1139101

ABSTRACT

RESUMEN El origen del pseudotumor orbitario no es del todo conocido. Se admite su naturaleza inflamatoria granulomatosa e inespecífica en diferentes localizaciones. El pseudotumor orbitario se define como una respuesta inflamatoria celular pleomórfica, que está usualmente confinado a estructuras de la órbita y tiene una evolución limitada. En este trabajo se presenta una paciente femenina de 16 años, con diagnóstico de pseudotumor orbitario corroborado por biopsia y tomografía axial computarizada, refractaria al tratamiento con esteroides sistémicos, por lo que se decide iniciar con la aplicación de hialuronidasa y triamcinolona en el espacio peribulbar. Los casos agudos casi siempre responden rápidamente al tratamiento con cortocoesteroides, como prednisona, pero debemos tener en cuenta que existen pacientes que son refractarios al tratamiento, por lo que es necesario buscar procedimientos alternativos. Una opción es el uso de hialuronidasa para destruir las uniones extracelulares, y difundir un esteroide de manera local, como la triamcinolona, más efectiva dentro del tejido inflamatorio para provocar un efecto localizado de este. A los tres meses del tratamiento hubo una regresión total del cuadro en esta paciente(AU)


ABSTRACT The exact etiology of orbital pseudotumor is unknown, but its granulomatous unspecific inflammatory nature at various locations has been recognized. Orbital pseudotumor is defined as a cellular pleomorphic inflammatory response of limited evolution often confined to orbital structures. A case is presented of a female 16-year-old patient diagnosed with orbital pseudotumor confirmed by biopsy and computerized axial tomography, refractory to treatment with systemic steroids, due to which it is decided to start treatment with hyaluronidase and triamcinolone in the peribulbar space. Acute cases often respond fast to treatment with corticosteroids such as prednisone. It should be borne in mind that there are patients who are refractory to treatment for whom alternative treatments should be sought. An option is the use of hyaluronidase to destroy extracellular junctions and locally spread a steroid such as triamcinolone, most effectively within the inflammatory tissue to ensure its localized effect. Total regression of the patient's status was observed at three months of treatment(AU)


Subject(s)
Humans , Female , Adolescent , Triamcinolone/therapeutic use , Orbital Pseudotumor/diagnosis , Hyaluronoglucosaminidase/therapeutic use
3.
Article | IMSEAR | ID: sea-185332

ABSTRACT

Purpose: To study the relationship between exophthalmometric values with age, gender and height of the normal Indian population. Methods:Cross-sectional, observational study of 2000 eyes of 1000 subjects aged 5 years to 90 years, from January 2016 to December 2016 (12 months),at Tertiary Care Hospital. Subjects who already had undergone routine ophthalmic examination and no abnormality was detected during the examination were included. The data about age, gender and height was noted. Exophthalmometry was performed using the same Hertel exophthalmometer by the same researcher. Results:The baseline exophthalmometric values in the normal Indian study subjects were in the range of 8-21 mm. Conclusions:Age and gender may have influence on exophthalmometric values; however, height does not have any significance

4.
Journal of Forensic Medicine ; (6): 353-356, 2017.
Article in Chinese | WPRIM | ID: wpr-667366

ABSTRACT

Objective To compare the differences between Hertel exophthalmometry and CT on exophthalmos measurement,and explore its practical application value in forensic medicine.Methods Fifty-six normal individuals without eye injuries or diseases were selected as the control group.The absolute values of exophthalmos were measured in the standardized CT image workstation.The difference of binocular exophthalmos was compared in normal group.Forty-seven cases with unilateral orbital fracture were divided into injured eye group and normal eye group according to the presence of binocular orbital fractures.The differences of the absolute values of eophthalmos from the same eye and the relative values of eophthalmos between two eyes for same person measured by Hertel exophthalmometry and CT were analyzed.Results There was no statistical difference of exophthalmos between the normal eyes measured by CT method.In the normal eye group,the absolute value of exophthalmos measured by CT method was (16.66±5.41) rm,which was (16.16±4.45)mm when measured by the Hertel exophthalmometry method.There was no statistical difference between two groups (P>0.05).In the injured eye group,there was statistical difference between the absolute values of exophthalmos measured by two measurement methods (P<0.05).There was no statistical difference of the relative values of exophthalmos between the injured eyes and the normal eyes by two measurement methods (P>0.05).Conclusion CT method has a good consistency with Hertel exophthalmometry,which can be applied into the practice of medicolegal expertise.

5.
Journal of the Korean Ophthalmological Society ; : 924-928, 2012.
Article in Korean | WPRIM | ID: wpr-183356

ABSTRACT

PURPOSE: To evaluate the usefulness of exophthalmos measurement on upgaze in patients who are not able to expose corneal vertex on primary gaze. METHODS: The present study included 39 patients with blow out fracture, pseudotumor, or thyroid associated ophthalmopathy and 21 people who don't have any ocular disease. In total, 60 people had exophthalmometry using Hertel exophthalmometer on the basis of corneal vertex, inferior limbus, and inferior sclera by three examiners. RESULTS: The relative exophthalmometry in normal group was 0.71 +/- 0.75 mm, 0.67 +/- 0.62 mm, and 0.69 +/- 0.60 mm on the basis of corneal vertex, inferior limbus, and inferior sclera, respectively. The relative exophthalmometry in exophthalmic group was 1.10 +/- 0.99 mm, 1.13 +/- 0.99 mm, 1.10 +/- 0.91 mm on the basis of corneal vertex, inferior limbus, and inferior sclera, respectively. The relative exophthalmometry in enophthalmic group was 0.79 +/- 0.90 mm, 0.74 +/- 0.92 mm, 0.74 +/- 0.87 mm on the basis of corneal vertex, inferior limbus, and inferior sclera, respectively. There was no statistically significant difference between different measuring points (p > 0.05). The inter-examiner reproducibility was shown to be highly reliable. CONCLUSIONS: The upgaze exophthalmometry on the basis of inferior limbus or inferior sclera would be useful in the patients who are not able to expose corneal vertex on primary gaze.


Subject(s)
Humans , Exophthalmos , Graves Ophthalmopathy , Sclera
SELECTION OF CITATIONS
SEARCH DETAIL